EXO2 Controlled Ozone System
EXO2 Controlled Ozone System
Core ozone injection system with one 20 g/h injector for canopy plenum or duct entry — smart dosing interlocked to airflow.

EXO2 Controlled Ozone System
Core ozone injection system with one 20 g/h injector for canopy plenum or duct entry — smart dosing interlocked to airflow.
Overview
Extechnology™ Controlled Ozone Systems — Smart, Safe, Compliant & Efficient odour control.
EXO systems provide core ozone injection at the canopy plenum or duct entry to neutralise kitchen odours.
The EXO2 uses one 20 g/h injector with smart dosing that responds to airflow/load and interlocks for safety.



Key Benefits

Smart odour neutralisation with responsive dosing to airflow and load.

Grease & fire‑risk reduction by breaking down deposits in the duct.

Lower maintenance: cleaner ductwork and longer intervals between cleans.

Safety & compliance: monitored discharge keeps ozone within recommended limits.

Efficient operation: low power, interlocked and BMS‑ready.

Smart odour neutralisation with responsive dosing to airflow and load.

Grease & fire‑risk reduction by breaking down deposits in the duct.

Lower maintenance: cleaner ductwork and longer intervals between cleans.

Safety & compliance: monitored discharge keeps ozone within recommended limits.

Efficient operation: low power, interlocked and BMS‑ready.

Smart odour neutralisation with responsive dosing to airflow and load.

Grease & fire‑risk reduction by breaking down deposits in the duct.

Lower maintenance: cleaner ductwork and longer intervals between cleans.

Safety & compliance: monitored discharge keeps ozone within recommended limits.

Efficient operation: low power, interlocked and BMS‑ready.
Specifications
Parameter | Value |
---|---|
Ozone output | 1 × 20 g/h injector |
Install location | Canopy plenum or duct entry |
Control | Smart dosing; airflow interlocked |
Electrical | 220–240 VAC, 50/60 Hz (typ.) |
BMS/IO | Run/fault contacts (typ.); airflow proving |
Complementary | Pair upstream with Rydair ESP for particulate capture |
Typical Applications
Hospitality & foodservice — restaurants, hotels, pubs and commercial kitchens.
Foodservice chains — catering operations, QSR and supermarket kitchens.
High‑odour environments — prep areas, staff canteens and retail food courts.
Maintenance
Visual inspection: check injectors/nozzles monthly; verify duct connections and seals.
Electrical & interlocks: confirm airflow proving and door interlock operation; test BMS/fault signals.
Ozone generation module: clean/inspect per manufacturer schedule; replace wear parts as specified.
Monitoring: verify setpoints/alarms; calibrate sensors every 6–12 months depending on duty.
Record keeping: maintain logbook entries for service and commissioning readings.
Typical Applications
Hospitality & foodservice — restaurants, hotels, pubs and commercial kitchens.
Foodservice chains — catering operations, QSR and supermarket kitchens.
High‑odour environments — prep areas, staff canteens and retail food courts.
Maintenance
Visual inspection: check injectors/nozzles monthly; verify duct connections and seals.
Electrical & interlocks: confirm airflow proving and door interlock operation; test BMS/fault signals.
Ozone generation module: clean/inspect per manufacturer schedule; replace wear parts as specified.
Monitoring: verify setpoints/alarms; calibrate sensors every 6–12 months depending on duty.
Record keeping: maintain logbook entries for service and commissioning readings.